Engineering notes

Choose the goods before you price the job

Engineer to engineer: signals, protocols, PoE, DDC — not a brochure. Also the glossary.

BMS and metering

BMS and metering

What does BMS equipment include? Field layer and DDC panel

BMS equipment list: sensors, valves, controllers, modules, protocol gateways, panel accessories.

BMS and metering

How to choose a sensor for a DDC: signal, range, supply

Choose a BMS sensor from the controller input: NTC, 0–10 V, 4–20 mA, dry contact.

BMS and metering

Choose a DDC from the I/O count

Size a DDC from analog and digital points, spare capacity and the protocol.

BMS and metering

BACnet and Modbus when you buy a BMS gateway

When a chiller already speaks BACnet or Modbus, and when you still need a gateway.

BMS and metering

BMS equipment lead time: order before ceilings close

Shelf sensors are not the same as a specified controller.

BMS and metering

BMS sensors: choose 0–10 V or 4–20 mA

When to use 0–10 V and when to use 4–20 mA on BMS sensors.

BMS and metering

BMS temperature sensors: NTC, PT100 or PT1000

How NTC, PT100 and PT1000 differ on a DDC.

BMS and metering

24 V for a DDC panel: add the load before you buy

Add controller, sensor, valve and relay current before you buy a 24 V supply.

BMS and metering

Interposing relays and dry contacts on a BMS panel

When a DDC needs an interposing relay before a motor circuit.

BMS and metering

Modbus energy meters for a BMS

Branch meters before anyone promises savings.

BMS and metering

A BACnet gateway when the chiller already has a protocol

When you still need a BACnet/Modbus converter between a chiller and the BMS.

BMS and metering

Building energy monitoring: main and branch meters

When the BMS must show kWh: choose main and branch meters, protocol and current transformers.

BMS and metering

ATS and generator contacts the BMS should see

Mains, generator and ATS status into the BMS: dry contacts, never 230 V into a digital input.

BMS and metering

Signal cable for sensors and valves

Choose signal cable: twisted pair, screen, keep it off power tray.

BMS and metering

When you need both a main meter and branch meters

A main meter matches the utility bill.

BMS and metering

Current transformers for energy meters

Choose a CT for main and branch meters: ratio, accuracy class, never leave the secondary open.

BMS and metering

Fire-alarm contacts the BMS should see

The BMS reads dry contacts from the fire panel: alarm, fault, test.

BMS and metering

How to lay out a controller cabinet

Lay out a DDC cabinet: split valve power, signal trunking, labels, spare module space.

BMS and metering

RS-485 on a BMS: termination, node count, noise

Modbus RTU and BACnet MS/TP ride RS-485.

BMS and metering

Signal-cable screens: earth one end

A screened pair earthed at both ends can carry a loop bigger than the 0–10 V.

BMS and metering

Dry contacts: NO or NC on the point list

On the same breaker, NO and NC reverse run/stop on the BMS.

BMS and metering

Meter pulses: when you do not yet need Modbus

One pulse contact and a kWh-per-pulse factor is enough for some files.

BMS and metering

Outdoor sensors: IP rating, sun, not an office head

An IP20 wall head on a metal roof dies in one wet season.

BMS and metering

Floats and level sensors: tanks and drain pans are not one part

A domestic tank, an AHU pan, a soil stack — three products.

BMS and metering

DDC or PLC: a shop-floor PLC is not an office AHU controller

A building DDC speaks BACnet and takes NTC heads.

BMS and metering

BACnet/IP or MS/TP: the same word, two kinds of cable

MS/TP rides RS-485.

BMS and metering

24 VAC or 24 VDC: valves and sensors are not one brick

Many modulating valves take 24 VAC.

BMS and metering

Humidity: room or duct — a combo head is not always two points

Room humidity is not duct humidity.

BMS and metering

Duplicate Modbus addresses: two meters as slave 1, half the bus goes dark

One address per slave.

BMS and metering

BACnet device IDs: a clash and the object disappears

Each DDC and gateway needs its own device instance.

BMS and metering

kWh and kvarh: if the file asks for power factor, the meter must see Q

Many branch meters only pulse kWh.

BMS and metering

RS-485 isolator or repeater: two boxes, two jobs

A repeater adds length and nodes.

HVAC

HVAC

Control valves and actuators for a BMS

Match valve size, pressure and actuator signal: 0–10 V, 4–20 mA, 24 V on/off.

HVAC

CO2 sensors on an AHU and in a meeting room

Where to put a CO2 sensor for demand-controlled ventilation.

HVAC

AHU filter differential-pressure sensors: range and tapping

Choose a filter ΔP sensor: pascal range, tappings before and after the filter, signal into the DDC.

HVAC

How a drive talks to the BMS

How a drive talks to the BMS: run/fault contacts, analog speed, or Modbus.

HVAC

Chilled-water pipe pressure sensors

Choose a chilled-water pressure sensor: bar range, 0–10 V or 4–20 mA, tap location.

HVAC

Choose a variable-speed drive from the motor

Size a drive from motor kW and current, pump or fan load, and EMC filters.

HVAC

EMC filters and chokes when you order a drive

A long motor cable over a sensitive BMS — an unfiltered drive makes 0–10 V sensors tick.

HVAC

Solenoid or modulating: two different orders

A solenoid is open or shut.

HVAC

FCUs: a room thermostat or a DDC point

Until the file says whether FCUs stand alone or report to the BMS, you have two schedules.

HVAC

VRV / VRF into the BMS: the maker’s gateway, not a room sensor

Per-indoor status on the BMS needs the air-con maker’s gateway.

HVAC

Pipe temperature: strap-on, immersion, or a well

A strap-on head is slow when the insulation is thick.

HVAC

Chilled-water flow switches: a tank float is not an AHU pipe

An AHU needs proof of flow before the chilled valve opens.

HVAC

Damper actuators: fire on/off is not an AHU modulating motor

A fire damper is often 230 V, two-position, spring-return.